Outils pour utilisateurs

Outils du site


beeceiverv2instructions

BeeCeiver Frsky V2 Instructions

The BeeCeiver v2 Frsky supports the following functions:

  • D8 and D16 as well as Futaba SFHSS protocols (switchable)
  • Diversity
  • Inverted and Un-Inverted S-Bus signal (switchable)

BINDING

To Bind the Beecieiver V2 you simply plug the battery in FIRST and then press the Bind button. The LED’s will start to blink like police lights…then go into your radio and put it into bind mode. The led’s will then change to a slow red blink…once you take your radio out of bind they will change to green to indicate bound.
The Rx should be set to D8 mode, please ensure your Model in the radio is set accordingly.

Un-inverted/Inverted Sbus modes

The Rx should come set to Un-inverted Sbus signal. The LED blink sequence will show you if the signal is Inverted or Un-Inverted.
There are two sets of LED blinks upon startup:
The first set will indicate Inverted or Un-Inverted Sbus signal.
For Un-inverted Sbus signal (reverse SBUS): After you power on the Rx the LED will flash RED twice.
For Inverted Sbus signal (regular Sbus and requires a hardware inverter on the FC, th BBBL does not): After power up the LED will blink BLUE twice.
This is a switchable function and easy to change. To change between Inverted and Un-Inverted Sbus, you simply just hold the bind button while plugging in the battery…one or two seconds is long enough. The signal will now be the opposite of what it was previously

If you get the Rx bound and you DO NOT see that BF is responding to your sticks, its possible that the Rx either came set to inverted or you accidentally changed it. Just follow the instructions to change it back and then you should see movement.

Frsky Protocol settings

The Rx is capable of supporting D8 (stock setting) D16 as well as Futaba SFHSS protocols. To Change between the 3:
While the Rx is powered on, double click the Bind button to cycle through the different protocol selections,the LEDs will blink:

  • RED for D8
  • GREEN for D16
  • BLUE for Futaba

You can tell what protocol is being used upon power up…the second set of Blinks will indicate this… red for D8, green for D16 and blue for Futaba.

Example 1:
Power up …..BLUE BLUE, RED RED, Solid Green. The Rx is using inverted Sbus(standard) it is in D8 mode and is bound (solid green after boot up, if not bound then the light will be a steady red blink after initial boot up.

Example 2:
Power up…RED RED, RED RED, Solid Green. Rx is using un-inverted Sbus (this is how it should be) D8, Bound.
The second set of blinks indicates the protocol mode.

beeceiverv2instructions.txt · Dernière modification : 25/03/2021 18:15 de wikiadmin

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki